Traditional Culture Encyclopedia - Traditional stories - What is the automated three-dimensional cold storage and its advantages and disadvantages

What is the automated three-dimensional cold storage and its advantages and disadvantages

Automated three-dimensional cold storage Xueyi refrigeration for your introduction:

One, the current situation of cold storage management and the main problems

01, the cold storage temperature classification, the working temperature range is not the same, specialized, difficult to manage;

02, the cold storage system of the switch are manually operated, the management of a large area, multi-storage room to bring a lot of work intensity;

03, cold storage management using manual inspection, often the inspection is not in place, can not find hidden faults, refrigeration systems do not get 24-hour guardianship;?

04, cold storage refrigeration system equipment failure is not found in a timely manner, resulting in increased loss of food, medicine, etc.;?

05, the actual temperature of the cold storage and equipment operation status data can not be collected in real time, in the production and storage of goods can not reflect the process of temperature, food, medicine storage environment can not be guaranteed, the quality inspection can not meet the standard, high-quality goods is the lack of persuasion and credibility.

Two, "centralized monitoring, centralized maintenance, unified management"?

01, the main monitoring of each cold storage temperature and humidity, carbon dioxide site, through the transmission to the measurement and control terminals, measurement and control terminals through the wireless communication network in the form of GSM \ GPRS will send data to the monitoring center.

02. Through the remote telemetry and control system, the maintenance personnel can inquire the operation status of the cold storage in real time, and realize the centralized management of the cold storage in several regions.

03. The monitoring center realizes real-time processing and analysis, storage, display and output of monitoring data, handles all the alarm information, records the alarm events, and sends the control commands of the backstage management personnel to each cold storage.

Third, the system overview:?

Value:

01, reduce the work intensity of the cold storage manager?

02, on-demand start and stop refrigeration system, energy saving, efficient management of real-time monitoring, fault alarms sent in a variety of ways to report real-time status of the equipment, refrigeration system to get 24-hour real-time guardianship, the potential for failure to get timely warning?

03, reduce the loss of food, medicine and other storage?

04, the actual temperature of the cold storage and equipment operating status data are collected in real time to improve the persuasive power and credibility of the quality of goods through the temperature and humidity, carbon dioxide sensors on the site of the cold storage room data convergence to the measurement and control terminals, measurement and control terminals through the GSM \ GPRS wireless network will send the data to the monitoring center, from the monitoring center to achieve the centralized management of the different cold storage. In case of equipment alarm, the alarm information will be forwarded to the cell phone of system maintenance personnel and cold storage management personnel in real time through the measurement and control terminal or monitoring center.

System composition:? The system consists of sensors, sound and light alarms, measurement and control terminals, monitoring center?

01, sensors and sound and light alarms installed in the cold storage, real-time monitoring of the cold storage environment indicators and site alarm;?

02, remote measurement and control terminal is mainly used to complete the real-time monitoring of temperature and carbon dioxide density in the cold storage workshop, and it can manage the temperature and carbon dioxide density through the monitoring center 24 hours a day. When the value of temperature and carbon dioxide density reaches the threshold, the remote measurement and control terminal can trigger the sound and light alarms, and at the same time, the remote measurement and control terminal will upload real-time information of the cold storage workshop to the monitoring center through the GPRS network and automatically send SMS alarms to the monitoring center and send the alarms to the monitoring center. At the same time, the remote measurement and control terminal will upload the real-time information of the cold storage workshop to the monitoring center through GPRS network and automatically send SMS alarm to the cell phone of the set maintenance personnel.

03. The monitoring center realizes the tasks of receiving, filtering, storing, processing, statistical analysis and providing real-time data query, so as to know the environmental index of each cold storage workshop in real time. When emergency events such as temperature and carbon dioxide density are too high or too low, the maintenance personnel can directly see the alarm information of each cold storage workshop through the monitoring page.

Four, the software platform function?

01, electronic map: visual display of cold storage equipment operation status;?

02, management rights: group setting rights to ensure system security;?

03, cycle setting: system administrators can flexibly set the cycle, to ensure that the monitoring center data in real time;

04, alarm management: the current alarm, the history of alarms, alarm statistics;?

05, report statistics: alarm data statistics report, polling data statistics report;?

06, log management: user login and exit, parameter modification, alarm forwarding, etc.;?

07, import and export: historical data import and export, export in various forms (excel, txt, html).