Traditional Culture Encyclopedia - Traditional virtues - Are underfloor heating modules any good? What is the difference between underfloor heating and traditional underfloor heating?

Are underfloor heating modules any good? What is the difference between underfloor heating and traditional underfloor heating?

Underfloor heating module is a new type of underfloor heating, in terms of thickness, is relatively thin, underfloor heating module in compression resistance, thermal conductivity, heat storage, safety and other aspects of the traditional underfloor heating has unparalleled advantages, the following is a detailed introduction to the underfloor heating module is good as well as underfloor warming and the traditional underfloor heating what is the difference between them, come to learn about it.

Underfloor heating module is a new type of underfloor heating, from the thickness is relatively thin, underfloor heating module in pressure resistance, thermal conductivity, heat storage, safety and other aspects of the traditional underfloor heating has unparalleled advantages, the following is a detailed introduction to the underfloor heating module is good as well as underfloor warming and the traditional underfloor warming what is the difference between them, come together to learn about it.

A floor heating module is good

The bottom of the ultra-thin floor heating module is connected by a line, the bottom retains part of the void, reducing the heat to the ground to pass the transfer medium needed, its thermal insulation is second only to the vacuum insulation. Ultra-thin module floor heating is 10℃ lower than traditional floor heating heat source, and the indoor temperature is 4-6℃ higher. Product ground with a raised, reduce the heat transfer down, thermal conductivity is less than the traditional foam template more than 5 times, high thermal efficiency, can reduce heat loss of more than 80%. The thickness of the product is only 2.6CM, small thermal resistance, short thermal range, heat storage and heat transfer fast.

Each piece of the ultra-thin floor heating module can be done under the pressure of a car does not deform, not rupture, with a strong anti-pressure, which can effectively protect the pipe to prevent the leakage caused by the pipe broken cases, but also to avoid the ground in the long-term state of deformation caused by the force, which is other floor heating module does not have. Therefore, the ultra-thin floor heating module is very suitable for factories, hospitals, hotels, shopping malls, and other places where large equipment and heavy furniture are stored.

Ultra-thin underfloor heating modules are lighter in weight, which can reduce the load on the floor. Because the ultra-thin floor heating module is stable, non-corrosive, super pressure resistance, the equipment is not affected by the outdoor temperature, greatly extending the life of the heating system. Aging resistance?50 years, the trial life is 6-10 times of the traditional heating piece, the service life is synchronized with the building. Therefore, the health and environmental protection of the ultra-thin floor heating module and the use of security is beyond reproach.

Ultra-thin floor heating module to polyethylene polypropylene for the production of materials, these materials are widely used in agricultural film, pharmaceuticals and food packaging film, visible Shuotai floor heating module of environmental protection. Ultra-thin floor heating module products are odorless, non-toxic, does not evaporate harmful gases, has excellent high temperature resistance, small water absorption, has good electrical properties and high-frequency insulation is not affected by humidity, but also has a certain degree of noise, flame retardant.

Relative to the traditional floor heating, ultra-thin floor heating module not only has many superior performance, but also more provincial installation and construction costs, eliminating the traditional floor heating concrete costs, etc., reducing the amount of factory. Similarly the safety of ultra-thin underfloor heating modules is also a key issue, should be entrusted to a professional floor heating company to install, on all aspects of the need to have a full set of quality control system.

Second, what is the difference between underfloor heating and traditional floor heating

1, pipe spacing

Pipe spacing determines, to some extent, the floor heating? The power of the floor heating. Pipe spacing is too dense or too sparse will affect the heating effect. Some warm friends even think that the floor heating is hot enough, all depends on the tube spacing, to some extent is established.

Traditional floor heating construction, tube spacing is based on the number of reflective film grid to determine. To really do? Horizontal and vertical card nail Qi? It takes a long time. Your time is money, the construction staff time is also money, and this money is paid by you.

So the actual construction can do? Horizontal and vertical card nail Qi? Few, spacing control effect is not good. More like the above picture does not control the spacing, disk up is.

2, dead fold

Dead fold is a situation that may occur in the construction of floor heating. Pipe dead fold will lead to poor water flow, water resistance becomes larger, and even pipe blockage does not circulate. The existence of mushroom head ensures that the pipe spacing is well controlled and avoids dead bends.

Of course, the turning part is made into ? Water drop head? Module to make a teardrop head around will be able to. But the traditional way, inexperienced masters can not even do it, and it is very time-consuming. So your underfloor heating does not have this elegant and practical? Water drop head? It is very normal.

3, nail

The traditional floor heating construction in the use of nails in a square meter 35-45, linear spacing in 30cm or so. It means that a square meter of insulation will be poked 70-90 holes. And the floor heating module coil does not need nails.

Nails are supposed to hold the coils in place, but they have a side effect: they destroy the integrity of the insulation. Above is a cross-section of a 20 pipe fixed to a 2cm thick extruded board using 20 nails. The tip of the nail part of the insulation board is only about 5mm thick, the insulation is weakened. Moreover, there may be concrete moisture in the nail holes.

It is even worse in corners. Especially in winter or using aluminum-plastic pipe, because the pipe stress is large, a turn needs 5-6 nails, the number of using poor quality nails will be more.

4, pipe suspension installation

The traditional installation wants to realize the pipe suspension installation, it is difficult. Wire mesh has a certain role in lifting the pipe, but can not be completely lifted. If realized by reducing the spacing of the wire mesh, the cost will be much higher.

Previously, a European company called ROTH introduced a concept of nails, can realize the suspension installation. But still a concept.

The module lifts the pipe mainly by the prongs on the module. The pipes are lifted and are in 360-degree contact with the concrete, speeding up heat dissipation and making it easier and more energy efficient for the heat to go upward.

5, construction safety

Backfill layer construction is needed to cover the construction, so as not to hurt the pipe. The pipes in the module are embedded in the middle of the mushroom head, which can better protect the pipes.

In the case of pipe leakage, part of the pipe is just beginning to be injured or scratched, when there is no leakage off pressure, but in the system under the action of water pressure, time will leak, not timely remediation, leakage of the eye will also become larger. It is very important to protect the pipeline.

6, connection

The integrity of the insulation directly determines the energy efficiency of floor heating, split heating without insulation is equal to the high cost of use. Traditional floor heating extruded plastic board seams and reflective film seams generally use special aluminum foil tape. Module using buckle groove, 0 gap, simple, convenient and effective.

7, construction efficiency

The traditional floor heating construction steps are complicated, from the side strip to the silicon crystal network requires 7 steps, the module only 3 steps. The traditional floor heating steps of labor requirements, construction results are difficult to control, depending on the quality of construction personnel to decide.

Module paving test can save 50% of the labor time, and the results are better and more standard. This is the European construction standardization, tooling, do not rely on the concept of human. Improvements in the product are used to ensure the quality of the finished result.

Maybe some of the warm friends will say, the construction price is basically certain, fast and slow that is the floor heating company's business.

In fact, it is not, consume more man hours, increased labor costs are certainly transferred to the consumer. And the complexity of the process will only increase the chance of making mistakes, resulting in the final product results vary, the pass rate can not be guaranteed.

The above is today to introduce to you about the floor heating module is good as well as underfloor heating and traditional underfloor heating what is the difference between the full knowledge, through this article, I believe you have an understanding of the floor heating module, I hope the above article can bring you help.