Traditional Culture Encyclopedia - Traditional festivals - How much load can a 100 kW generator carry?
How much load can a 100 kW generator carry?
How many loads can a 300 kW generator carry? Different weights have certain differences. Take Cummins as an example and model HQCM300XNGF as an example. The specific reference number is the basic data of the generator set: the model of the generator set is 300 kW diesel engine, the model is Chongqing Cummins NTA855-G2A diesel engine, and the number of cylinders is 6. The common power is 3 13KW, and the standby power is 343KW. The rated fuel consumption (g/KW.h) 196 cylinder diameter.
How much load can a 250 kW generator carry? I want to know what diesel engine your generator is equipped with. Generally, the power factor written on the generator is 0.8, that is, the actual 250KW generator is 250*0.8, which is equal to 200KW. The actual situation may be less than 200KW, that is, the maximum drive 180 or 190.
Also consider the start-up of electrical equipment. The starting current of many electrical equipment is very large, for example, the starting current of a general motor is about 4 to 7 times the rated current. The generator is too small to start.
How much load can a 7.5 kW three-phase generator carry per phase? It depends on your voltage. You can test the current of the motor, as long as the current does not exceed 15A, it can be used normally.
How much load can a 400KW diesel generator set carry? The 400KW generator set can provide 400 kW active power, 500KVA capacity and 300 kva reactive power.
How many electrical appliances can a 120kW generator carry? It can work with 120kW three-phase balanced load for a long time. If the three phases are unbalanced, the maximum phase cannot be overloaded. At this time, the load it carries is only the sum of three phases.
How many loads can a 500 kW gasoline generator carry? This cannot be simply calculated by power. But it should be calculated according to the rated current. In other words, the total current of the load cannot be greater than the rated output current of the generator. Under a purely resistive load, the load power may be equal to the power of the generator. But not a pure resistance load. Don't look at power, look at current.
How many three-phase motors can a 50 kW generator carry at full load for 8 hours? Without special measures, a 50 kW diesel generator can drive a 12KW motor at most, because:
1, the starting current of the motor is 4~7 times of the rated current. 8 kW motor is difficult to start normally. The starting time is long and the generator can bear it. The diesel engine is overloaded and on the verge of stopping working.
2. Using some measures to reduce the starting current can slightly improve the power of the motor:
A. star triangle is adopted to start conversion,
B. after no-load start, reload,
C, the use of soft start auxiliary device, help start, etc.
How many aerators can a 23KW generator hold? Take 3kW as one, and connect up to 6 aerators. Start cannot be started at once. It's best to start two sets at a time.
How many kilowatts can the 15kva generator carry? Electrical appliances are determined according to their power factor. Generally, 10~ 13kW is acceptable.
- Previous article:Catalogue of landscape design of garden plants
- Next article:How about Jiangsu Hai Metal Material Co., Ltd.?
- Related articles
- What is the main color of the exterior wall of the China Pavilion of the World Expo?
- When was the last Winter Olympics held?
- How much do you know about Tik Tok's business philosophy?
- How to install curtains with hooks
- What are the snacks in Shaxian County, Fujian Province?
- Write a 400-word essay on the topic of love my Fenxi,love my hometown
- How to make soybean sprouts and mung bean sprouts at home?
- Introduction to Peritoneal Dialysis
- What is China's consistently pursued foreign policy
- How to write a lecture notes for sophomore English