Traditional Culture Encyclopedia - Traditional festivals - How to handle the third-level qualification of fire engineering? What are the requirements?

How to handle the third-level qualification of fire engineering? What are the requirements?

The contracting qualification of fire protection facilities engineering specialty is divided into grade one and grade two.

Level 1 qualification standard:

1, enterprise assets

Net assets 10 million yuan or more.

2. The main personnel of the enterprise (1) shall be no less than 5 first-class registered construction engineers of mechanical and electrical specialty.

(2) The technical director has more than 10 years working experience in technical management of fire control facilities engineering construction, and has the senior title of engineering sequence; There are not less than 10 people with intermediate or above titles in HVAC, water supply and drainage, electrical and automation majors, and the majors are complete.

(3) There shall be no less than 20 construction site management personnel with certificates, and the builder, quality engineer, safety officer, material engineer and documenter shall be complete.

(4) There shall be no less than 30 skilled workers at or above the intermediate level who have passed the examination or training.

3, enterprise engineering performance

In recent five years, he has undertaken two fire control facilities projects with a single building area of over 40,000 square meters (each project includes automatic fire alarm system, automatic fire extinguishing system and smoke control and extraction system), and the project quality is qualified.

Secondary qualification standard:

1, enterprise assets

The net assets are more than 6 million yuan.

2. Key personnel of the enterprise

(1) There shall be no less than 3 registered construction engineers in mechanical and electrical specialty.

(2) The technical director has more than 8 years' experience in technical management of fire control facilities engineering construction, and has the senior title of engineering sequence or the qualification of first-class registered constructor of electromechanical engineering; There are not less than 6 people with intermediate or above titles in HVAC, water supply and drainage, electrical and automation, and their majors are complete.

(3) There are not less than 65,438+05 construction site management personnel with certificates, and the builders, quality controllers, safety officers, materials engineers and librarians are complete.

(4) There shall be no less than 20 skilled workers at or above the intermediate level who have passed the examination or training.

(5) The technical director (or registered constructor) shall preside over the completion of not less than two engineering achievements required by the first-class qualification standard of this category.

Scope of contracted projects

First-class enterprise: can undertake the construction of various fire-fighting facilities.

Secondary enterprise: it can undertake the construction of the following fire-fighting facilities with a single building area of less than 50,000 square meters:

(1) Civil buildings other than Class I high-rise civil buildings;

(2) Factories, warehouses, storage tanks and storage yards with fire risk below Class C. ..

Note: The classification of civil buildings and the fire hazard classification of workshops, warehouses, storage tanks and storage yards are determined according to the Code for Fire Protection Design of Buildings (GB500 16-20 14).